Middle EastSMEC Oil & Gas Solutions LLCinfo@smecong.com+971 50 249 1903

IndiaSMEC Automation Pvt Ltdsales@smecong.com+91 86060 47714

Digital Platforms

NexWave Remote Asset Monitoring

NexWave connects selected data from PLCs, sensors, meters and SCADA to a remote operating view. It is intended for distributed assets where teams need current status, trends, alarms and engineering visibility without treating every data point as an AI prediction.

NexWave logo above a laptop showing an SMEC monitoring dashboard of gauges and charts
NexWave — Remote Monitoring

Core scope

  • Multi-site dashboards
  • Tag trends and alarm visibility
  • Gateway/protocol integration
  • Role-based remote access
  • Condition and threshold monitoring
  • Cloud or project-approved architecture
  • Remote engineering support

SMEC role

SMEC is the engineering bridge between the physical asset, OT data source, communications layer and operating workflow. Integration is defined against the installed system rather than assuming a greenfield data stack.

Project evidence

  • Case studyOffshore drilling rig

    Offshore Drilling Rig — Real-Time Remote Monitoring of Drilling Instrument Parameters

    Problem · SMEC scope · Architecture
    Problem
    An offshore oil and gas operator needed secure, real-time access to critical drilling instrument parameters from remote offices, without modifying the existing control systems.
    SMEC scope
    SMEC designed and deployed a real-time remote monitoring system on its own Edge IoT unit, reading data already available in the existing Drilling Management System (DMS) PLC — no additional instrumentation — and publishing it to an authenticated cloud application.
    Architecture
    Ethernet handshake between the DMS PLC and the SMEC Edge IoT unit over CAT 6 cabling and industrial-grade switches; data pushed to AWS Cloud at user-configurable intervals, with up to 4 concurrent authenticated users per location and error alerts on remote PCs if the internet link fails.

Common questions

Can this solution work with existing systems?

Installed-base compatibility is assessed first. Integration depends on available PLC/SCADA, camera, protocol, network and data interfaces and on project cybersecurity requirements.

Does implementation require replacing existing equipment?

Not necessarily. The preferred approach is to determine what can remain, what data can be exposed safely and what interface or edge components are required.

What information is needed to assess feasibility?

Share the existing architecture, make/model, available protocols or data sources, required use case, site/network constraints and the decisions or events that need to be visible.

Have a NexWave project to discuss?

Share the existing equipment, drawings, project location and scope of work.

Send the asset list, existing PLC/SCADA, required tags/events, sites/users and network/cloud constraints. Recommended RFQ inputs: project/asset, existing OEM/model, scope, drawings or specification, required date, site location, and any shutdown/mobilization constraint.

Submit RFQ