Middle EastSMEC Oil & Gas Solutions LLCinfo@smecong.com+971 50 249 1903

IndiaSMEC Automation Pvt Ltdsales@smecong.com+91 86060 47714

Product system

Flare Boom Pilot Ignition System

Delivering the most reliable pilot ignition system for you

A flare ignition system must reliably deliver ignition energy from the control point to the pilot under the environmental and hazardous-area conditions of the installation. SMEC supports engineered ignition packages including ignition points, HEA cards/tips, HV cables, pilot interfaces, hazardous-area junction/control panels, field stations and commissioning.

An SMEC flare ignition package laid out: an open stainless panel with four ignition modules, a control box with push buttons, a junction box with cable glands, ignition probes and two high-energy ignition units

About the Flare Boom Pilot Ignition System

Standards and specifications

Standard Energy12 Joules
Spark Rate Per Second> 5 Sparks
Input Voltage110 or 230 V AC, 50/60 Hz
Duty Cycle15 Mins On & 15 Mins Off (1:1)
Maximum Current5 Amps

Features

Why SMEC?

  • High Energy Ignition
  • Natural Draft Pilot
  • Compact Design
  • Cost Effective
  • MOC SS316
  • High Temperature Resistance Steel Braided Cables
  • Explosion Proof
  • Stainless Steel Panels
  • Longer Life
  • Easy Maintenance
  • Insensitive to Moisture & Dirt Easy Retrofit
  • Optional Flame Monitoring AC and DC Input
  • Options Cable Length Up to 150 Meters

Reliable Pilot Ignition Begins with the Entire Ignition Circuit

A flare pilot ignition package must be engineered around the pilot arrangement, ignition energy, cable routing, environmental exposure and safe operating procedure. SMEC's scope can include ignition controls, field junction boxes, high-voltage cables and status interfaces as specified.

Technical scope / product architecture

  • Multiple ignition-point architecture as project-defined
  • HEA cards/tips
  • High-voltage ignition cables
  • Pilot interfaces
  • Ex-proof SS316 junction/control panels where specified
  • Hazardous-area glands/terminals to approved project requirements
  • Local pushbutton/field station
  • FAT, installation and commissioning

What SMEC adds

Engineering, interface definition, panel/package build, software/configuration where applicable, FAT, site installation support, SAT/commissioning and lifecycle support.

How it works

Ignition path — An ignition control panel energises pilot ignition devices through specified cables, field junction boxes and ignition hardware.

Pilot arrangement — Pilot count, tip arrangement, distance and environmental exposure influence the ignition architecture.

Feedback — Flame proving or ignition status indication is specified separately from the act of generating a spark.

Field installation — HV insulation, earthing, Ex-rated equipment and safe test procedures are essential for offshore and process-area installations.

Key components

Ignition control panel. Panel layout, ingress protection, segregation, component selection and service clearance follow the installation environment, load schedule and maintenance requirements.

Ignition cards. The ignition cards is selected for the equipment, operating duty and site conditions.

Pilot igniters and tips. Pilot ignition depends on the complete circuit: ignition energy, electrodes, high-voltage cable condition, earthing and the site operating procedure.

High-voltage cable interfaces. The high-voltage cable interfaces is selected for the equipment, operating duty and site conditions.

Field junction boxes. The field junction boxes is selected for the equipment, operating duty and site conditions.

Pushbutton stations. The pushbutton stations is selected for the equipment, operating duty and site conditions.

Status feedback. The status feedback is selected for the equipment, operating duty and site conditions.

Hazardous-area equipment. The hazardous-area equipment is selected for the equipment, operating duty and site conditions.

Upgrades & retrofits

Replace ignition cards, HV cabling and field junction boxes as needed.

Add pilot points or local/remote initiation stations to an approved sequence.

Introduce flame status feedback where supported by the pilot arrangement.

Retrofit scope depends on existing OEM interfaces, component condition, available space, shutdown windows and the approval basis of any safety-related functions.

Applications

  • Offshore platforms
  • Well testing
  • Production facilities
  • Refineries

Testing & documentation

Relevant IEC, ISO, API, classification-society, hazardous-area or functional-safety requirements must be selected according to the specific system and installation. Where applicable, the project package may include electrical drawings, GA layouts, datasheets, I/O schedules, cause-and-effect, communication lists, inspection records, FAT/SAT procedures, calibration records and as-built documents. No unverified compliance certification is claimed here.

Common questions

Can Flare Pilot Ignition System be supplied for new build, retrofit or replacement?

The lifecycle route depends on the installed base, condition, interfaces, obsolescence and project requirements. SMEC can assess new-build, retrofit, repair or replacement scope where technically valid.

Can existing field wiring or interfaces be retained?

Possibly. Retention depends on survey findings, condition, ratings, compatibility, safety requirements, documentation and the cutover strategy.

What information is required for quotation?

Send the make/model or required specification, datasheets, drawings, ratings, interfaces, fault details where applicable, site location and required date or shutdown/mobilization window.

Can an old ignition panel be replaced while retaining pilot hardware?

Sometimes, after compatibility and condition checks.

Is flame detection included?

It can be specified as an interface or package element, but must be explicitly defined.

What should the RFQ include?

Pilot count, existing ignition arrangement, drawings, hazardous-area rating and site conditions.

Other SMEC systems

Every system is built to the rig it serves and integrated with the rest of the installation.

All systems

Have a Flare Boom Pilot Ignition System project to discuss?

Share the existing equipment, drawings, project location and scope of work.

Send the datasheet/specification, existing make/model (if retrofit), drawings and required delivery/mobilization date. Recommended RFQ inputs: project/asset, existing OEM/model, scope, drawings or specification, required date, site location, and any shutdown/mobilization constraint.

Submit RFQ