Product system
Jack-Up Rig Jacking Control & Rack Phase Difference (RPD) Monitoring Systems
Coordinated Jacking Control. Precise RPD Monitoring. Engineered for Rig Modernisation.
SMEC provides Jack-Up Rig Jacking Control Systems and Rack Phase Difference (RPD) Monitoring Solutions for offshore self-elevating drilling rigs.
Our engineering capabilities cover PLC-based jacking controls, motor and brake interfaces, central operator consoles, leg-position monitoring, RPD measurement, alarms and system modernisation.
From new control-system integration to legacy jacking system retrofits, SMEC supports project-specific electrical, automation and monitoring requirements around existing jack-up machinery.
- Jacking Control Systems
- RPD Monitoring
- PLC/HMI Upgrades
- Rig Life Extension

Jacking Control Systems for Offshore Jack-Up Rigs
Coordinated Control Across Motors, Brakes and Rig Legs
Jack-up rig elevation requires coordinated operation of jacking motors, drives, braking systems and leg-position interfaces.
SMEC engineers jacking control systems around installed machinery, approved operating sequences and existing OEM interfaces.
Jacking Control Capabilities
- PLC-based jacking control and central operator HMI
- Electric motor and drive-control interfaces
- Hydraulic jacking control interfaces, where applicable
- Motor-group sequencing and operating permissives
- Brake-release logic and status monitoring
- Leg-position, speed and selected load-related feedback
- Alarm, fault and diagnostic monitoring
- Existing jacking control system upgrades and retrofits
Control functions depend on the approved jacking machinery configuration, operating philosophy and project requirements.
Rack Phase Difference (RPD) Monitoring System
Different Rack Positions. Critical Information During Jacking.
Rack Phase Difference (RPD) is the relative vertical displacement between corresponding rack positions on different chords of a jack-up rig leg.
Monitoring RPD helps operators identify differential movement between leg chords during jacking operations and assess the condition against defined operating limits.
SMEC's RPD monitoring solution provides measurement and operator indication of rack phase differences, supporting controlled jacking operations and monitoring of leg-chord displacement.
RPD Monitoring Capabilities
- Rack phase measurement using compatible daisy-wheel sensor arrangements
- Individual leg-chord position measurement
- Rack Phase Difference calculation and display
- Monitoring across multiple jack-up rig legs
- Operator indication of relative chord displacement
- Configurable warning and alarm interfaces
- Integration with jacking console and monitoring displays
- Sensor, controller and display modernisation
For a typical three-leg jack-up rig with three monitored chords per leg, the configuration may use nine sensing positions. Final sensor arrangements depend on the rig design.
RPD alarm limits and protective responses must follow the approved rig-specific operating requirements.
Jacking Control & RPD System Architecture
| System Component | Typical Function |
|---|---|
| Central Jacking Control Console | Operator commands, equipment status and alarms |
| PLC & Remote I/O | Jacking control logic and machinery interfaces |
| Motor & Drive Interfaces | Motor-group sequencing, operating feedback and diagnostics |
| Brake Control Interfaces | Brake status, release permissives and fault monitoring |
| Leg Position Monitoring | Leg movement and position-related information |
| RPD Sensors | Measurement of individual rack-chord displacement |
| RPD Monitoring Controller | Signal processing and differential position calculations |
| RPD Display & Alarms | Operator indication, warnings and diagnostic information |
How the Systems Work Together
1. Jacking Control
The central control system coordinates approved motor, drive and brake operations during rig elevation and lowering.
2. Position & RPD Measurement
Leg-position and RPD sensors provide measurement information about relevant rig-leg movement and relative chord displacement.
3. Operator Monitoring
The jacking console displays operating conditions, machinery feedback, RPD values and configured alarms.
4. Operating Limits & Interlocks
Control permissives, alarms and any approved protective responses are implemented according to the rig's operating philosophy and validated control design.
Jacking Control & RPD System Upgrades
Modernise Existing Controls. Retain Compatible Jacking Machinery.
SMEC supports the assessment and modernisation of existing jacking control and monitoring installations, including:
- Replacement of obsolete jacking PLCs and HMIs
- Central jacking console modernisation
- Motor, drive and brake-control interface upgrades
- RPD sensor and monitoring-system upgrades
- Leg-position monitoring integration
- Alarm, diagnostic and event-monitoring improvements
- Integration with compatible existing OEM machinery
Existing motors, gearboxes, brakes and other mechanical equipment may be retained where technically suitable and approved.
Applications
- Offshore Jack-Up Drilling Rigs
- Jacking Control Modernisation
- RPD Monitoring Upgrades
- Rig Refurbishment
- Rig Reactivation
- Rig Life Extension
SMEC Engineering, Testing & Commissioning
SMEC supports jacking control and RPD monitoring assessments, PLC/HMI engineering, sensor and machinery interfaces, panel integration, system configuration and project-specific documentation.
Depending on the approved scope, services may include Factory Acceptance Testing (FAT), functional simulation, installation support, Site Acceptance Testing (SAT), commissioning and lifecycle technical assistance.
Machinery protection, emergency-stop arrangements, RPD operating limits and safety-related control functions require appropriate engineering verification and approval.
Frequently Asked Questions
What is a jack-up rig jacking control system?
A jacking control system coordinates the machinery used to raise and lower a jack-up rig relative to its legs. Depending on the equipment design, it integrates motor and drive controls, braking interfaces, operating interlocks, leg-position information and operator monitoring.
What is an RPD monitoring system?
A Rack Phase Difference monitoring system measures relative vertical displacement between corresponding rack positions on different chords of a jack-up rig leg. It provides operators with information and alarms for assessing differential chord movement during jacking operations.
What is the difference between Jacking Control and RPD Monitoring?
Jacking Control manages approved machinery commands, motor operation, braking and interlocks. RPD Monitoring measures and indicates relative displacement between rack chords. The systems can be integrated for operator visibility, but their functions remain distinct.
Can SMEC upgrade an existing jacking control and RPD system?
Yes. SMEC can assess existing PLCs, operator consoles, control interfaces, RPD sensors and monitoring equipment for modernisation or replacement, subject to OEM compatibility and engineering requirements.
Does an RPD system automatically stop jacking operations?
Not necessarily. An RPD system may provide measurement, indication and alarms. Automatic stop functions can only be claimed where they are part of an approved and validated protection arrangement.
What information is required for a quotation?
Share the jack-up rig design, jacking-system OEM, existing PLC/HMI details, number and arrangement of legs and chords, RPD sensor information, relevant drawings, identified problems and proposed upgrade scope.
Other SMEC systems
Every system is built to the rig it serves and integrated with the rest of the installation.

Power Houses
PCR House | SCR House | VFD House
Know More
CCTV & AI Video Surveillance
See More Than Footage. Detect What Matters. Respond with Better Information.
Know More
Drill Monitor System
Real-Time Drilling Data. Configurable Rig Monitoring. Engineered for Modernisation.
Know More
Integrated Drilling Control System
Elevate Your Drilling: Precision Meets Innovation with SMEC’s Integrated Control System!
Know More
Request a Jacking Control & RPD Technical Assessment
Upgrading a Jacking Console? Replacing an RPD Monitoring System?
SMEC can assess existing jacking control and RPD monitoring arrangements and develop a project-specific engineering and retrofit proposal.
AE · Middle East & International
SMEC Oil & Gas Solutions LLC
Abu Dhabi, UAE
IN · India
SMEC Automation Pvt Ltd
Kochi, Kerala, India
