Product system
Industrial Battery Chargers & DC Power Supply Systems
Reliable DC Power. Intelligent Battery Charging. Engineered for Critical Industrial Applications.
SMEC provides industrial battery chargers, battery charging panels and DC power supply system engineering for oil & gas, marine, offshore installations, power plants and industrial facilities.
Designed to support control circuits, protection relays, emergency auxiliaries and other designated DC loads, our solutions integrate automatic battery charging, electrical protection, battery-bank interfaces, monitoring and DC distribution.
SMEC supports new installations, replacement battery chargers, industrial DC system upgrades and project-specific electrical integration.
- 12V / 24V / 48V DC Chargers
- Battery Charging Panels
- DC Distribution
- System Retrofits

Industrial Battery Charging & DC Power Systems
When AC Power Is Interrupted, Critical DC Loads Still Need Power.
Industrial control and protection systems often rely on battery-backed DC supplies to maintain specified functions during AC supply interruptions.
SMEC engineers charger and DC distribution arrangements around battery capacity, connected loads, required autonomy, charging characteristics and installation conditions.
Solutions can include charger units, battery-bank interfaces, DC protection and distribution, local indication and remote alarm connections.
Battery Charger Features
- Automatic three-stage battery charging
- 12 V, 24 V and 48 V DC output configurations
- Charger ratings up to 100 A within the listed range
- Galvanic isolation
- LED status indication
- Current regulation and battery charging control
- Overvoltage, overcurrent, overload, overtemperature and short-circuit protection
- Forced-air cooling
- Optional temperature sensing and voltage compensation
- Charger and battery alarm interfaces
- Project-specific DC distribution and monitoring integration
Features and ratings are model-dependent. Battery compatibility and charging profiles must be verified for the selected battery chemistry.
Industrial Battery Charger Technical Specifications
| Parameter | Listed Specification |
|---|---|
| Nominal DC Output | 12 / 24 / 48 V DC |
| Charging Current | 10 / 20 / 40 / 100 A |
| Battery Capacity Range | 200–1000 Ah |
| Nominal AC Input | 110 / 230 / 415 V AC, 50/60 Hz |
| Input Voltage Tolerance | ±10% |
| Charging Method | Automatic three-stage |
| Battery Outlets | 1 |
| Display | LED indication |
| Galvanic Isolation | Yes |
| Cooling | Forced air |
| Operating Temperature | 0°C to +55°C |
| Protection Rating | IP23 |
| Optional Features | Temperature sensor and DC voltage compensation |
Model-specific charging values: The supplied specifications list 28.5 V absorption and 26.5 V float voltage. These are 24 V-class settings and must not be applied universally to 12 V or 48 V models. Battery chemistry and manufacturer requirements determine appropriate charging settings.
Battery Charger & DC System Integration
Battery Charging
Automatic charging stages regulate battery charging according to the selected battery type and configuration.
Battery-Backed DC Supply
Battery banks support defined DC loads during an AC power interruption, subject to available battery capacity and system design.
Protection & DC Distribution
DC protection devices, feeder arrangements and monitoring interfaces are configured according to the connected equipment and installation requirements.
Monitoring & Alarm Interfaces
Selected charger status, battery condition and electrical alarms can be integrated with compatible PLC, SCADA or supervisory systems.
Battery Charger Upgrades & Retrofits
Existing DC System. Ageing Charger or Unsupported Components?
SMEC supports:
- Industrial battery charger replacement
- Charger and battery-bank interface upgrades
- DC distribution-panel modifications
- Monitoring and alarm integration
- Electrical protection and control-component replacement
- Existing charger-panel modernisation
Retrofit feasibility depends on battery chemistry, charger compatibility, battery condition, electrical ratings and existing system architecture.
Industrial Applications
- Oil & Gas Facilities
- Offshore Rigs
- Marine Vessels
- Power Plants
- Electrical Substations
- Industrial Automation
- Utilities
SMEC Engineering, Testing & Support
SMEC supports technical assessments, charger selection, battery and DC load evaluation, panel engineering, electrical integration and project documentation.
Depending on scope, services may include Factory Acceptance Testing (FAT), installation support, Site Acceptance Testing (SAT), commissioning and lifecycle technical assistance.
Frequently Asked Questions
What is an industrial battery charger?
An industrial battery charger converts an AC supply into regulated DC power for charging a battery bank. Depending on the system architecture, it can also support connected DC loads used in industrial control, protection and auxiliary applications.
What is the difference between a battery charger and a DC power supply system?
A battery charger manages battery charging. A complete DC power supply system may additionally incorporate battery banks, DC distribution, protection, monitoring and backup-power arrangements.
Can SMEC supply 12V, 24V and 48V DC battery chargers?
The published SMEC range lists 12 V, 24 V and 48 V DC configurations, with charging-current options of 10, 20, 40 and 100 A. Availability and technical specifications must be confirmed for the selected model.
Can an existing industrial battery charger be replaced?
Yes. SMEC can assess the existing charger's output voltage, charging current, battery chemistry, capacity, protection and installation interfaces to determine a suitable replacement.
What information is required for a battery charger quotation?
Share the DC system voltage, battery type and capacity (Ah), charging-current requirements, connected DC loads, required backup duration, AC input supply, installation environment and project location.
Other SMEC systems
Every system is built to the rig it serves and integrated with the rest of the installation.

Power Houses
PCR House | SCR House | VFD House
Know More
CCTV & AI Video Surveillance
See More Than Footage. Detect What Matters. Respond with Better Information.
Know More
Drill Monitor System
Real-Time Drilling Data. Configurable Rig Monitoring. Engineered for Modernisation.
Know More
Integrated Drilling Control System
Elevate Your Drilling: Precision Meets Innovation with SMEC’s Integrated Control System!
Know More
Request an Industrial Battery Charger Technical Quotation
New DC Power System? Obsolete Battery Charger? Planning an Upgrade?
SMEC can review the DC power requirements and develop a project-specific battery charger, panel or electrical integration proposal.
AE · Middle East & International
SMEC Oil & Gas Solutions LLC
Abu Dhabi, UAE
IN · India
SMEC Automation Pvt Ltd
Kochi, Kerala, India
