Product system
Generator Control & Power Management Systems (PMS)
Synchronisation. Load Sharing. Blackout Recovery. Engineered for Power Continuity.
SMEC provides generator control and power management system (PMS) engineering, integration and retrofit solutions for drilling rigs, offshore platforms, marine vessels and industrial power plants.
Our engineering scope covers automatic generator synchronisation, active and reactive load sharing, priority load shedding, generator start/stop sequences, breaker controls and power-system monitoring.
From new installations to legacy PMS upgrades, SMEC develops project-specific solutions around the existing generators, switchboards, protection systems and operating requirements.
- Generator Synchronisation
- Load Sharing & Shedding
- PMS Retrofits
- Blackout Recovery

Generator Power Management That Responds When Conditions Change
Managing the Load Is Only Half the Job. Managing the Transition Matters.
Generator power management becomes critical when electrical demand increases, an online generator trips, or a power system needs to recover after a blackout.
SMEC engineers generator control and PMS solutions to coordinate generator availability, electrical load distribution, breaker operations and approved recovery sequences.
System functions are configured around the plant's electrical architecture, generator capacity, load priorities and operating philosophy.
Generator PMS Features & Capabilities
- Automatic generator synchronisation and breaker interfaces
- Active power (kW) and reactive power (kVAr) load-sharing interfaces
- Generator auto-start and stop sequencing
- Priority load shedding and load management
- Bus-tie control and operating-mode coordination
- Generator governor and Automatic Voltage Regulator (AVR) interfaces
- Blackout detection and approved recovery sequences
- SCADA/HMI monitoring, alarms and event diagnostics
- Legacy generator controller and PMS upgrades
Available functions depend on the approved system design, generator controls, protection architecture and project scope.
How the Generator Power Management System Works
Generator Synchronisation
Controls and monitors the conditions for connecting generators to an electrical bus, including voltage, frequency, phase angle and breaker permissives.
Load Sharing
Coordinates active and reactive power distribution among online generators through compatible governor, AVR and generator-control interfaces.
Load Shedding
Initiates approved load-reduction or disconnection sequences when available generating capacity becomes insufficient, according to defined load priorities.
Blackout Recovery
Coordinates permitted generator restarting, bus restoration and staged load reconnection according to the approved recovery philosophy.
System Architecture & Key Components
| Component | Typical Function |
|---|---|
| Generator Controllers | Generator operating modes, start/stop commands and status |
| Synchronising Controls | Voltage, frequency, phase-angle checks and breaker closing |
| Governor & AVR Interfaces | Active and reactive power-sharing control |
| PMS Controller / PLC | Power management logic and approved operating sequences |
| Bus-Tie & Breaker Interfaces | Switchboard status, permissives and control |
| Load-Shedding Logic | Priority-based load reduction or disconnection |
| HMI / SCADA | Power-system visualisation, alarms and diagnostics |
Generator PMS Upgrades & Retrofits
Existing Generators. Obsolete Power Management Controls?
SMEC supports generator control and legacy PMS modernisation through:
- Replacement of obsolete synchronisers and PMS controllers
- Generator control-panel and HMI upgrades
- Load-sharing and load-shedding logic modifications
- Integration of additional generators into existing power systems
- Bus-tie control and communication-interface modernisation
- Alarm, event-monitoring and blackout-recovery improvements
Existing generators, breakers and suitable control equipment may be retained following technical assessment.
Retrofit feasibility depends on governor/AVR compatibility, protection coordination, switchboard architecture and verified operating sequences.
Applications
- Drilling Rigs
- Offshore Platforms
- Marine Vessels
- Captive Power Plants
- Industrial Power Systems
SMEC Engineering, Testing & Commissioning
SMEC supports power-system assessments, control architecture development, electrical panel engineering, generator interface integration, PLC/HMI configuration and technical documentation.
Depending on project requirements, services may include Factory Acceptance Testing (FAT), control-sequence simulation, Site Acceptance Testing (SAT), commissioning and lifecycle support.
Generator protection, blackout recovery, bus transfers and operating interlocks must be verified against approved electrical designs and applicable project requirements.
Frequently Asked Questions
What is a Generator Power Management System (PMS)?
A Generator PMS coordinates generator availability, synchronisation, load sharing, breaker interfaces and electrical load management. Depending on system configuration, it may also support automatic generator starting, priority load shedding and blackout recovery.
What is the difference between load sharing and load shedding?
Load sharing distributes electrical demand among generators operating in parallel. Load shedding disconnects or reduces selected electrical loads when available generating capacity is insufficient, helping manage overload conditions according to approved priorities.
Can SMEC upgrade an existing generator PMS without replacing the generators?
Yes, where technically feasible. SMEC can assess existing generator controllers, synchronisers, PLCs, switchboards and governor/AVR interfaces for partial modernisation or control-system replacement.
Can a PMS help prevent electrical blackouts?
A properly engineered PMS can support blackout prevention through generator availability management, load sharing, load shedding and other approved control functions. It cannot eliminate all blackout risks, which also depend on generator performance, protection systems and electrical network conditions.
Can SMEC integrate additional generators into an existing PMS?
SMEC can assess additional generator integration requirements, including synchronisation, load sharing, breaker controls, operating sequences and protection coordination. The feasibility depends on generator ratings and the existing electrical system.
What information is required for a Generator PMS quotation?
Share generator ratings and quantities, single-line diagram (SLD), switchboard and breaker details, existing PMS make/model, governor/AVR information, load list, protection philosophy, blackout-recovery requirements and project location.
Request a Generator Control & PMS Technical Assessment
Legacy PMS? Generator Synchronisation Upgrade? Planning an Additional Genset?
SMEC can evaluate the existing power-management architecture and develop a project-specific engineering, integration or retrofit proposal.
AE · Middle East & International
SMEC Oil & Gas Solutions LLC
Abu Dhabi, UAE
IN · India
SMEC Automation Pvt Ltd
Kochi, Kerala, India
