Automatic Fire Fighting Control System

Automatic fire-fighting control coordinates detection, alarm, release and status functions for an approved suppression system. SMEC should position the control/integration scope and avoid claiming suppression design beyond licensed/project capability.

An open PLC panel on a pallet, its controllers, I/O modules and terminal rows in view

System architecture / typical scope

  • Detection inputs
  • Release control panel
  • Solenoid/actuator outputs
  • Abort/manual release
  • Alarm/beacon interfaces
  • F&G/ESD integration where required

What SMEC can support

  • Requirements and interface review
  • Detailed engineering and approved component selection
  • Panel/package build or integration within SMEC capability
  • Software/configuration where applicable
  • FAT and documentation
  • Site integration, SAT and commissioning
  • Retrofit, troubleshooting and lifecycle support

Applications

Industrial rooms, equipment enclosures, marine/offshore and process facilities according to approved fire strategy.

Project evidence

  • Case studyPetroleum installation

    Petroleum Installation — Automatic Fire Fighting System with Redundant SIL PLC and SCADA

    Problem · SMEC scope · Architecture · Testing
    Problem
    The facility needed an automatic fire fighting system where a failure in the suppression logic, signal loss over long cable runs, inconsistent pressure data or a clogged solenoid valve could not be allowed to compromise the response to a fire.
    SMEC scope
    SMEC supplied and installed redundant SIL PLC control panels integrated with a SCADA system, signal, control and optical fiber cabling, pressure transmitters and solenoid valves, and carried out the civil works — cable trays and panel foundations — within the timeline.
    Architecture
    Dual-redundant SIL-rated PLC panels with automatic switchover on panel or logic failure, integrated with SCADA; cabling and fiber routed to minimise EMI between valves, transmitters and PLCs; solenoid valves with upstream strainers and filters.
    Testing
    Pressure transmitters calibrated to OEM standards and verified through simulation testing; the system was erected, tested and commissioned, and the client certified the work complete.

Common questions

Can Automatic Fire Fighting Control System be supplied for new build, retrofit or replacement?

The lifecycle route depends on the installed base, condition, interfaces, obsolescence and project requirements. SMEC can assess new-build, retrofit, repair or replacement scope where technically valid.

Can existing field wiring or interfaces be retained?

Possibly. Retention depends on survey findings, condition, ratings, compatibility, safety requirements, documentation and the cutover strategy.

What information is required for quotation?

Send the make/model or required specification, datasheets, drawings, ratings, interfaces, fault details where applicable, site location and required date or shutdown/mobilization window.

Have an Automatic Fire Fighting Control System project to discuss?

Share the existing equipment, drawings, project location and scope of work.

Fire strategy, suppression type, cause/effect, detector/release list, area classification and authority/class requirements.

Submit RFQ