Plant Automation & SCADA Systems

Plant automation connects field instruments, motors, drives, package controls and operator supervision into one maintainable operating architecture.

An engineer at a bank of monitoring screens with an offshore drilling rig beyond the window

System architecture / typical scope

  • PLC/remote I/O
  • HMI/SCADA
  • Drives/MCC interfaces
  • Instrumentation
  • Networks/protocols
  • Historian/remote monitoring
  • FAT/SAT

What SMEC can support

  • Requirements and interface review
  • Detailed engineering and approved component selection
  • Panel/package build or integration within SMEC capability
  • Software/configuration where applicable
  • FAT and documentation
  • Site integration, SAT and commissioning
  • Retrofit, troubleshooting and lifecycle support

Applications

Heavy industry, utilities, water, manufacturing, energy and infrastructure.

Project evidence

  • Case studyPetroleum installation

    Petroleum Installation — Automatic Fire Fighting System with Redundant SIL PLC and SCADA

    Problem · SMEC scope · Architecture · Testing
    Problem
    The facility needed an automatic fire fighting system where a failure in the suppression logic, signal loss over long cable runs, inconsistent pressure data or a clogged solenoid valve could not be allowed to compromise the response to a fire.
    SMEC scope
    SMEC supplied and installed redundant SIL PLC control panels integrated with a SCADA system, signal, control and optical fiber cabling, pressure transmitters and solenoid valves, and carried out the civil works — cable trays and panel foundations — within the timeline.
    Architecture
    Dual-redundant SIL-rated PLC panels with automatic switchover on panel or logic failure, integrated with SCADA; cabling and fiber routed to minimise EMI between valves, transmitters and PLCs; solenoid valves with upstream strainers and filters.
    Testing
    Pressure transmitters calibrated to OEM standards and verified through simulation testing; the system was erected, tested and commissioned, and the client certified the work complete.

Common questions

Can Plant Automation & SCADA Systems be supplied for new build, retrofit or replacement?

The lifecycle route depends on the installed base, condition, interfaces, obsolescence and project requirements. SMEC can assess new-build, retrofit, repair or replacement scope where technically valid.

Can existing field wiring or interfaces be retained?

Possibly. Retention depends on survey findings, condition, ratings, compatibility, safety requirements, documentation and the cutover strategy.

What information is required for quotation?

Send the make/model or required specification, datasheets, drawings, ratings, interfaces, fault details where applicable, site location and required date or shutdown/mobilization window.

Have a Plant Automation & SCADA Systems project to discuss?

Share the existing equipment, drawings, project location and scope of work.

P&IDs, I/O, control narrative, SLD, equipment list, existing PLC/SCADA and project objectives.

Submit RFQ