Engineering Support for NOCs
NOCs operate long-life asset portfolios where reliability, standardization, lifecycle support, local execution and documentation matter as much as initial CAPEX. SMEC supports project-specific E&I, automation, brownfield modernization, rig systems and digitalization with regional execution and India engineering depth.

NOCs
Typical engagement
- Lifecycle/obsolescence assessments
- Brownfield control migration
- Rig and offshore modernization
- E&I packages and shutdown support
- E-Houses and electrical integration
- Remote monitoring, CMMS and digital twin use cases
Project evidence

Offshore Drilling Rigs — In-Situ Repair of AC and DC Modules, PCBs and ACBs
Problem · SMEC scope · Testing · Outcome
- Problem
- Under a rate contract, the operator needed a partner to diagnose and repair complex PCB systems across critical rig zones — driller’s console, engine room and control room — on non-standard legacy hardware degraded by salt-laden air, including failing surge suppression and power limit PCBs that affected generator safety.
- SMEC scope
- SMEC deployed a marine electronics team for in-situ and workshop repair of AC and DC modules, PCBs, heat sink–IGBT assemblies and air circuit breakers: reverse engineering of damaged PCBs on proprietary test jigs, hot-swap module servicing to keep rigs running, remote support to rig crews, and tracked logistics from the helibase to SMEC’s facility and back.
- Testing
- Functional simulation of generator exciter and auxiliary motor control PCBs before reinstallation; onboard functional testing with portable test benches and calibrated instruments; electro-thermal profiling of heat sinks; testing and calibration of 460V/600V AC ACBs. Every job documented with test logs and compliance records.
- Outcome
- PCB turnaround cut from 10–12 days to 72–96 hours; equipment downtime from 18+ hours to under 6 hours on average; ACB fault recurrence from 2x a month to 0 over 90 days+; field module failure below 1% after service, with 100% component functionality restored.

Petroleum Installation — Automatic Fire Fighting System with Redundant SIL PLC and SCADA
Problem · SMEC scope · Architecture · Testing
- Problem
- The facility needed an automatic fire fighting system where a failure in the suppression logic, signal loss over long cable runs, inconsistent pressure data or a clogged solenoid valve could not be allowed to compromise the response to a fire.
- SMEC scope
- SMEC supplied and installed redundant SIL PLC control panels integrated with a SCADA system, signal, control and optical fiber cabling, pressure transmitters and solenoid valves, and carried out the civil works — cable trays and panel foundations — within the timeline.
- Architecture
- Dual-redundant SIL-rated PLC panels with automatic switchover on panel or logic failure, integrated with SCADA; cabling and fiber routed to minimise EMI between valves, transmitters and PLCs; solenoid valves with upstream strainers and filters.
- Testing
- Pressure transmitters calibrated to OEM standards and verified through simulation testing; the system was erected, tested and commissioned, and the client certified the work complete.
Related industries
Have a NOCs project to discuss?
Share the existing equipment, drawings, project location and scope of work.
Send the asset class, installed base and approved project scope. Recommended RFQ inputs: project/asset, existing OEM/model, scope, drawings or specification, required date, site location, and any shutdown/mobilization constraint.